Rope Access Fall Factors

News | June 11, 2024

MCL
Blog

Understanding Fall Factors: The Key to Managing Fall Forces

When a rope catches a falling load, the forces generated depend on the weight of the load, the distance it falls, and the length of the rope between the load and the anchor. This relationship is quantified as the fall factor, calculated by dividing the fall distance by the length of the rope.

For example, if a load falls 4 feet while secured by 8 feet of rope, the fall factor is 0.5.

As a rule of safe practice, wherever possible, do not work in a position in which the fall factor would be greater than one e.g., never work with your body above the anchor point. 

 

It’s All About the Factor

It may seem counterintuitive, but falling 20 feet on 40 feet of rope creates similar forces—and the same fall factor—as falling 4 feet on 8 feet of rope or 1 foot on 2 feet of rope. Each scenario results in a fall factor of 0.5.

While the likelihood of injury from hitting objects increases with a longer fall, the impact forces are comparable. However, there’s an inherent risk of hitting the ground. Falling from 10 feet above the ground while attached to 11 feet of rope is dangerous.

The Danger Zone

The fall factor is effective because it compares the fall distance to the rope length, which absorbs energy by stretching. Even a small fall on a very short rope can generate high forces. For instance, falling 1 metre on 1 metre of rope results in a fall factor of 1.0, generating significant force.

The highest risk of a high fall factor accident occurs when there is slack in the system and you are close to the anchor point. For rescuers, this is a critical concern when approaching the edge. Combining the weight of a rescuer and a patient increases the forces, potentially leading to gear failure.

Maximum Fall Factor

Generally, the maximum fall factor for rescuers and climbers is 2.0. This occurs when a rescuer falls twice the length of the rope. A fall factor of 2.0 can happen whether falling 2 feet on 1 foot of rope or 20 feet on 10 feet of rope. Such a fall factor is likely to cause injuries unless the system includes components to absorb the impact.

In rare cases, a fall factor can exceed 2.0, especially if the rope attachment can travel, leading to extreme forces.

How Much is Too Much?

OSHA specifies a maximum fall distance of 6 feet, regardless of the fall factor. They also mandate that the maximum force must not exceed 4 kN (900 pounds) when using a body belt and 8 kN (1800 pounds) with a body harness.

Consider the following data, assuming the rope has 10% elongation:

  • A 165-pound (75 kg) rescuer experiencing a 0.25 fall factor (falling 2 feet on 8 feet of rope) will generate about 4 kN of force (the maximum for a body belt).
  • The same rescuer with a 2.0 fall factor (falling 6 feet on 3 feet of rope) would generate around 6 kN.
  • A 225-pound (100 kg) rescuer with a 0.25 fall factor will also generate about 4 kN of force.
  • A 225-pound rescuer with a 1.5 fall factor (falling 6 feet on 4 feet of rope) would generate about 8 kN.

The Small Print

The actual forces generated by a fall depend on the load, fall factor, and the energy absorption capacity of the ropes, knots, harness, and the rescuer’s body. For instance, a 0.5 fall factor on dynamic climbing rope produces much less force than the same fall on a low-stretch rescue rope.

While the fall factor concept—maintaining constant force if the fall factor remains constant—is theoretically sound, actual forces increase with longer falls when using low-stretch ropes, even if the fall factor remains constant. This increase is small at a 0.25 fall factor but significant at higher fall factors.

Despite this, understanding fall factors is crucial. Rescuers must recognise that higher fall factors dramatically increase impact forces, necessitating diligent efforts to minimise potential fall factors.

For more information, visit IRATA ICOP and explore Petzl Fall Factor tests.

More information on Fall Factors is included as part of our IRATA training held in South London, East London and Humberside